– 36  –
MAC9512086C2
CS-C181KE
Technical Data
LL
LL
L Operation characteristics
CS-C181K / CU-C181K
• Piping Length Characteristic
• Cooling Characteristic
 PIPING LENGTH (m)
52515 2010
12
11
10
9
13
12.5
12
11.5
11
4.5
4.4
4.3
4.2
4.1
6.0
5.5
5.0
4.5
4.0
220V
240V 
I:                                                  Q:
Current (A)                           
-
    Cooling Capacity  (kW)                                
-
LP:                                                              O: Outlet
Gas Side Piping Pressure (kgf/cm
2
)           
- 
Air Temperature (°C)                 
-
[Condition]  Room temperature: 27/19°C
                   Outdoor temperature: 35/24°C
                   Cooling operation: At High fan
• Cooling Characteristic •  Piping Length Characteristic
15
14
13
12
12.5
12
11.5
11
10.5
4.0
3.9
3.8
3.7
7.0
6.5
6.0
5.5
5.0
4.5
 PIPING LENGTH (m)
52515 2010
220V
240V 
I:                                                  Q:
Current (A)                           
-
    Cooling Capacity  (kW)                                
-
LP:                                                              O: Outlet
Gas Side Piping Pressure (kgf/cm
2
)           
- 
Air Temperature (°C)                 
-
[Condition]  Room temperature: 27/19°C
                   Outdoor temperature: 35/24°C
                   Cooling operation: At High fan
CS-C241K / CU-C241K
    30      32       34      36      38      40      42       44   
 OUTDOOR  AIR TEMPERATURE (°C)
[Condition]  Room temperature: 27/19°C
                   Cooling operation: At High fan
                   Piping length: 7.5 m
16
15
14
13
12
12.5
12
11.5
11
10.5
10
4.2
4.1
4.0
3.9
3.8
7.5
7.0
6.5
6.0
5.5
5.0
220V
240V 
I:                                                       Q:
Current (A)                              -     Cooling Capacity (kW)                          -
LP:                                                              O: Outlet
Gas Side Piping Pressure (kgf/cm
2
)           
- 
Air Temperature (°C)                 
-
    30       32      34      36      38      40       42      44       
      OUTDOOR ROOM TEMPERATURE (°C)
[Condition]  Room temperature: 27/19°C
                   Cooling operation: At High fan
                   Piping length: 7.5 m
13
12
11
10
9
13
12.5
12
11.5
11
4.6
4.5
4.4
4.3
4.2
6.0
5.5
5.0
4.5
4.0
3.5
220V
240V 
I:                                                 Q:
Current (A)                           
-
   Cooling Capacity (kW)                              
-
LP:                                                              O: Outlet
Gas Side Piping Pressure (kgf/cm
2
)           
- 
Air Temperature (°C)                 
-
Untitled-7 6/19/00, 5:31 PM36