Anti-Dew Formation is control by:
Increasing Air Flow Volume
1. Lo fan speed
Lo fan speed is changed to Lo+ after 30 min to prevent dew formation.
2. QLo fan speed
Dew formation may occurs at QLo cool, therefore QLo cool is operated only 1 hr 30 min (1 hr QLo, 30 min QLo + 80 rpm).
After that, it operates at QLo +160rpm (However Quiet LED remains on).
Narrowing
1. Vertical Airflow Direction
During Anti-dew condensation prevention, Airflow Direction Auto-control angle change from - 32° to 20° - 30° under
Cooling and Soft Dry operation mode.