EasyManua.ls Logo

Panasonic CS-C9DKZW - Indoor Fan Motor and Cross Flow Fan Removal Procedures

Panasonic CS-C9DKZW
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 4
To remove the electronic controller.
Remove the particular piece (Fig. 4)
Release CN-FM connector (Fig. 4)
Release CN-Sonic connector (Fig. 4)
Release CN-FB connector (Fig. 4)
Release CN-ION connector (Fig. 4)
Remove Control Board cover
Fig. 6
Remove the screw on the left side of the unit. (Fig. 6)
Pull the hook to the left and lift up the evaporator. (Fig.
6)
Pull down the Discharge Grille Complete. (Fig. 6)
Release CN-TH connector (Fig. 4)
Release CN-STM connector (Fig. 4)
Release CN-REC/DISP connector (Fig. 4)
Fig. 5
Press the hook to the right then take out the PCB(Fig. 5)
Remove Ry-Pwr connector (black and brown) and Ac-
Wht connector from the PCB. (Fig. 5)
Fig. 7
Fig. 8
Remove indoor pipe sensor and air intake sensor from
the evaporator. (Fig. 7)
12.3. Indoor Fan Motor and Cross Flow Fan Removal Procedures
55
CS-C9DKZW CU-2C18DKH / CS-C9DKZW CU-3C20DKH

Table of Contents