EasyManua.ls Logo

Panasonic CS-C9PKV - Page 44

Panasonic CS-C9PKV
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
12.2.4 Connect the Cable to the Indoor Unit
1. The inside and outside connection cable can be
connected without removing the front grille.
2. Connection cable between indoor unit and
outdoor unit shall be approved polychloroprene
sheathed 4 × 1.5 mm
2
flexible cord, type
designation 60245 IEC 57 or heavier cord. Do not
use joint connection cable. Replace the wire if the
existing wire (from concealed wiring, or otherwise)
is too short.
Secure the connection cable onto the control board with the holder.
WARNING
This equipment must be properly earthed.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.