5
2. Specifications
Indoor CS-CE9PKE
Model
Outdoor CU-CE9PKE
Performance Test Condition EUROVENT
Phase, Hz Single, 50
Power Supply
V 230
Min. Mid. Max.
kW 0.85 2.50 3.00
BTU/h 2900 8530 10200
Capacity
kcal/h 730 2150 2580
Running Current A – 2.60 –
Input Power W 190 545 740
Annual Consumption kWh – 273 –
W/W 4.47 4.59 4.05
BTU/hW 15.26 15.65 13.78
EER
kcal/hW 3.84 3.94 3.49
Pdesign kW 2.5
SEER (W/W) 6.8
Annual
Consumption
kWh 129
ErP
Class A++
Power Factor % – 91 –
dB-A 39 / 25
Indoor Noise (H / L)
Power Level dB 55 / -
dB-A 46 / -
Cooling
Outdoor Noise (H / L)
Power Level dB 61 / -
kW 0.85 3.40 5.10
BTU/h 2900 11600 17400
Capacity
kcal/h 730 2920 4390
Running Current A – 3.55 –
Input Power W 185 740 1.35k
W/W 4.59 4.59 3.78
BTU/hW 15.68 15.68 12.89
COP
kcal/hW 3.95 3.95 3.25
Pdesign kW 2.8
Tbivalent °C -10
SCOP (W/W) 3.9
Annual
Consumption
kWh 1005
ErP
Class A
Power Factor % – 91 –
dB-A 40 / 27
Indoor Noise (H / L)
Power Level dB 56 / -
dB-A 47 / -
Heating
Outdoor Noise (H / L)
Power Level dB 62 / -
Low Temp. : Capacity (kW) / I. Power (W) / COP 3.70 / 1.19k / 3.11
Extr Low Temp. : Capacity (kW) / I. Power (W) / COP 3.22 / 1.23k / 2.62
Max Current (A) / Max Input Power (W) 6.0 / 1.35k
Starting Current (A) 3.55