86
18. Service Data
Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.
18.1 Cool Mode Outdoor Air Temperature Characteristic
Condition
• Indoor room temperature: 27°C DryBulb/19°C Wet Bulb
• Unit setting: Standard piping length, forced cooling at 16°C, Hi fan
• Compressor frequency: Rated for cooling operation
• Voltage: 230V
18.1.1 CS-CE9PKE / CU-CE9PKE
Current (A)Low Pressure (Mpa)
Outdoor Air Temperature (ºC)
Outdoor Air Temperature (ºC)
Outlet Air (ºC)
Outdoor Air Temperature (ºC)
2.00
2.30
2.60
2.90
3.20
3.50
30 31 32 33 34 35 36 37 38 39 40 41 42 43
1.020
1.040
1.060
1.080
1.100
1.120
30 31 32 33 34 35 36 37 38 39 40 41 42 43
15.00
15.50
16.00
16.50
17.00
17.50
30 31 32 33 34 35 36 37 38 39 40 41 42 43