C. Control contents
a. Air flow volume manual
1. Fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi & Me for 3dB & Lo for 2dB.
2. Quiet setting of fan speed is as shown in the following table.
E9CKP E12CKP/E15CKP
Quiet Hi SHi-100 SHi-100
Quiet Me Me-100 Me-100
Quiet Lo HLo-100 HLo-100
b. Air flow volume Auto
If FM
Lo
-100rpm shift
If FM
Lo
maintain RPM
Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.
8.3. Ionizer Operation
Purpose
To provide fresh air effect to user by producing minus ion in discharge air.
Control Condition
a. Ionizer Only Operation.
1. When air-conditioner unit is at OFF condition (standby) and ION operation button at remocon is pressed.
Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1 2)
However, fan speed can be adjusted later by customer during this operation.
Air flow direction (Horizontal Vane) control:
Follow vane direction control at cooling mode.
Horizontal vane can be changed by customer during ion only operation.
34
CS-E15CKP CU-E15CKP5

Other manuals for Panasonic CS-E15CKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E15CKP and is the answer not in the manual?

Panasonic CS-E15CKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-E15CKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals