8.2.22. Indication Panel
Led POWER MONITOR POWER QUIET TIMER POWERFUL ION
Color Green Green Orange Orange Orange Green
Light ON Operation ON Operation ON Quiet Mode ON Timer Setting ON Powerful Mode ON Ion Mode ON
Light OFF Operation OFF Operation OFF Quiet Mode OFF Timer Setting OFF Powerful Mode OFF Ion Mode OFF
Note:
•
If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode
judgment, or delay ON timer sampling.
•
If Timer LED is blinking, there is an abnormality operation occurs.
LED Control Frequency
Lighting of 3 LED base on instructed running frequency from indoor unit to compressor at cool, dry & heating operation.
Position of LED
Cool, Dry
Instructed Hz No
1~6 7~12 Fc ~ Fc max
Heat
Instructed Hz No
1~7 8~16 Fh above
Ion only operation — — —
8.2.23. Auto Operation Switch
1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.
2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.
3. When the switch is pressed between 8 to 11 seconds, the unit is forced to operate in Heating Mode.
4. When the switch is pressed between 11 to 16 seconds and together with the signal from remote control, the unit can be
changed to different controlling setting (A-B mode).
5. When the switch is pressed between 16 to 21 seconds, either “H14” error detection selection mode or the remote controller´s
signal receiving sound can be cancelled or turned on.
31
CS-E15CKP CU-E15CKP5