EasyManuals Logo

Panasonic CS-E15NKEW Service Manual

Panasonic CS-E15NKEW
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
116
16.4.19 F11 (4-way valve Abnormality)
Malfunction Decision Conditions
When heating operation, when indoor pipe temperature is below 10°C
When cooling operation, when indoor pipe temperature is above 45°C
Malfunction Caused
Connector in poor contact
Faulty sensor
Faulty outdoor unit PCB
4-way valve defective
Troubleshooting

Table of Contents