EasyManuals Logo

Panasonic CS-E15NKEW Service Manual

Panasonic CS-E15NKEW
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
123
16.4.26 F97 (Compressor Overheating)
Malfunction Decision Conditions
During operation of cooling and heating, when compressor tank temperature data (112°C) is detected by the
compressor tank temperature sensor.
Malfunction Caused
Faulty compressor tank temperature sensor
2/3 way valve closed
Refrigerant shortage (refrigerant leakage)
Faulty outdoor unit PCB
Faulty compressor
Troubleshooting

Table of Contents

Other manuals for Panasonic CS-E15NKEW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E15NKEW and is the answer not in the manual?

Panasonic CS-E15NKEW Specifications

General IconGeneral
BrandPanasonic
ModelCS-E15NKEW
CategoryAir Conditioner
LanguageEnglish

Related product manuals