14
Indoor CS-E12NKEW, CS-XE12NKEW
Model
Outdoor CU-E12NKE-3
Performance Test Condition EUROVENT
Phase, Hz Single, 50
Power Supply
V 230
Min. Mid. Max.
kW 0.85 3.50 4.00
BTU/h 2900 11900 13600
Capacity
Kcal/h 730 3010 3440
Running Current A - 4.1 -
Input Power W 250 905 1.18k
Annual Consumption kWh - 453 -
W/W 3.40 3.87 3.39
BTU/hW 11.60 13.15 11.53
EER
Kcal/hW 2.92 3.33 2.92
Power Factor % - 96 -
dB-A 42 / 28 / 20
Indoor Noise (H / L / QLo)
Power Level dB 58 / -
dB-A 48 / -
Cooling
Outdoor Noise (H / L)
Power Level dB 63 / -
kW 0.85 4.40 6.70
BTU/h 2900 15000 22800
Capacity
Kcal/h 730 3780 5760
Running Current A - 5.1 -
Input Power W 245 1.09k 1.93k
W/W 3.47 4.04 3.47
BTU/hW 11.84 13.76 11.81
COP
Kcal/hW 2.98 3.47 2.98
Power Factor % - 93 -
dB-A 42 / 33 / 20
Indoor Noise (H / L / QLo)
Power Level dB 58 / -
dB-A 50 / -
Heating
Outdoor Noise (H / L)
Power Level dB 65 / -
Low Temp. : Capacity (kW) / I.Power (W) / COP 4.85 / 1.67k / 2.90
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 3.75 / 1.68k / 2.23
Max Current (A) / Max Input Power (W) 8.9 / 1.93k
Starting Current (A) 5.1
Type Hermetic Motor (Rotary)
Motor Type Brushless (6-poles)
Compressor
Output Power W 700