146
Piping Length Characteristic
[Condition] Indoor temperature: 27/19°C, 35/-°C
Remote condition: High fan speed, Cool 16°C
Comp. Hz: F
c
3.200
3.300
3.400
3.500
3.600
3456789101112131415
Piping Length (m)
Cooling
Capacity (kW)
3.800
3.900
4.000
4.100
3456789101112131415
Piping Length (m)
Current
(A)
0.920
0.930
0.940
0.950
0.960
0.970
0.980
3 4 5 6 7 8 9 10 11 12 13 14 15
Piping Length (m)
Gas Side Piping
Pressure (MPa
)
15.200
15.400
15.600
15.800
16.000
3456789101112131415
Piping Length (m)
Outlet Air
Temperature (°C
)
230