2.2. CS-E21EKU CU-E21EKU
Unit CS-E21EKU CU-E21EKU
Performance Test Condition CSA
Cooling Capacity kW
BTu/h
6.10 (1.30 - 6.85)
20,800 (4,400 - 23,400)
Heating Capacity kW
BTu/h
6.90 (1.30 - 8.30)
23,400 (4,400 - 28,200)
Moisture Removal l/h
Pint/h
2.6
5.5
Power Source (Phase, Voltage, Cycle) ø
V
Hz
Single
208 - 230
60
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Lo m
3
/min (cfm) Cooling; 11.4 (404)
Heating; 12.6 (445)
Me m
3
/min (cfm) Cooling; 13.1 (462)
Heating; 14.5 (513)
Hi m
3
/min (cfm) Cooling; 14.7 (520) Cooling; 42.8 (1,510)
Heating; 16.5 (580) Heating; 41.5 (1,460)
SHi m
3
/min (cfm)
dB (A) Cooling; High 46, Low 39 Cooling; 48 - 48
Heating; High 47, Low 39 Heating; 49 - 49
Noise Level
Power level dB Cooling; High 59 Cooling; High 61
Heating; High 60 Heating; High 62
Electrical Data Input W Cooling; 2.15k (250 - 2.45k)
Heating; 2.15k (250 - 2.60k)
Running Current A Cooling; 10.7 - 9.7
Heating; 10.7 - 9.7
EER W/W (kcal/hw) Cooling; 2.84 (9.67)
COP W/W (kcal/hw) Heating; 3.21 (10.88)
Starting Current A 10.7
SEER/HSPF W/W 16.50 7.70
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 1/2”
L ; Half Union 1/4”
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
Drain
Hose
Inner diameter inch 20/32”
Length inch 25 - 19/32”
Power Cord Length
Number of core-wire
70 - 29/32”
(1.5mm
2
)
7