7
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor
-7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Indoor Operation Range
Cooling Maximum 32 23 32 23
Minimum 16 11 16 11
Heating Maximum 30 — 30 —
Minimum 16 — 16 —
Outdoor Operation Range
Cooling Maximum 43 26 43 26
Minimum 5 4 5 4
Heating Maximum 24 18 24 18
Minimum -5 -6 -5 -6
MODEL INDOOR CS-E7LKEW, CS-XE7LKEW CS-E9LKEW, CS-XE9LKEW
OUTDOOR CU-E7LKE CU-E9LKE