8
MODEL INDOOR CS-E12LKEW, CS-XE12LKEW CS-E15LKEW, CS-XE15LKEW
OUTDOOR CU-E12LKE CU-E15LKE
Performance Test Condition EUROVENT EUROVENT
Power Supply
Phase, Hz Single, 50 Single, 50
V 230 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.80 3.50 4.00 0.80 4.20 5.00
BTU/h 2730 11900 13600 2730 14300 17100
Kcal/h 690 3010 3440 690 3610 4300
Running Current A — 3.9 — — 5.7 —
Input Power W 185 860 1.13k 195 1.26k 1.57k
Annual Consumption kWh — 430 — — 630 —
EER
W/W 4.32 4.07 3.54 4.10 3.33 3.18
Kcal/hW 3.73 3.50 3.04 3.54 2.87 2.74
Power Factor % — 96 — — 96 —
Indoor Noise (H / L / QLo)
dB-A 42 / 28 / 20 43 / 31 / 25
Power Level dB 58 / 44 / 36 59 / 47 / 41
Outdoor Noise (H / L)
dB-A 48 / - 49 / -
Power Level dB 63 / - 64 / -
Heating
Capacity
kW 0.80 4.00 6.00 0.80 5.30 6.80
BTU/h 2730 13600 20500 2730 18100 23200
Kcal/h 690 3440 5160 690 4560 5850
Running Current A — 4.4 — — 6.6 —
Input Power W 175 950 1.71k 185 1.44k 1.94k
COP
W/W 4.57 4.21 3.51 4.32 3.68 3.51
Kcal/hW 3.94 3.62 3.02 3.73 3.17 3.02
Power Factor % — 94 — — 95 —
Indoor Noise (H / L / QLo)
dB-A 42 / 33 / 20 43 / 35 / 29
Power Level dB 58 / 49 / 36 59 / 51 / 45
Outdoor Noise (H / L)
dB-A 50 / - 51 / -
Power Level dB 65 / - 66 / -
Low Temp. : Capacity (kW) / I.Power (W) / COP 4.47 / 1.48k / 3.02 4.92 / 1.72k / 2.86
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 3.46 / 1.49k / 2.32 3.94 / 1.83k / 2.15
Max Current (A) / Max Input Power (W) 7.8 / 1.71k 9.0 / 1.94k
Starting Current (A) 4.4 6.6
Compressor
Type Hermetic Motor Hermetic Motor
Motor Type Brushless (4-poles) Brushless (6-poles)
Output Power W 700 700
Indoor Fan
Type Cross-flow Fan Cross-flow Fan
Material ASG20K1 ASG20K1
Motor Type Transistor (8-poles) Transistor (8-poles)
Input Power W — —
Output Power W 40 40
Speed
QLo
Cool rpm 630 730
Heat rpm 670 900
Lo
Cool rpm 830 870
Heat rpm 1010 1080
Me
Cool rpm 1040 1070
Heat rpm 1150 1210
Hi
Cool rpm 1260 1270
Heat rpm 1300 1350
SHi
Cool rpm 1320 1340
Heat rpm 1340 1370