Piping Length Characteristic
[Condition] Indoor temperature: 20/-°C, 7/6°C
Remote condition: High fan speed, Heat 30°C
Comp. Hz: F
h
4.200
4.250
4.300
4.350
4.400
4.450
3456789101112131415
Piping Length (m)
Heating
Capacity (kW)
2.420
2.440
2.460
2.480
3 4 5 6 7 8 9 10 11 12 13 14 15
Piping Length (m)
Gas Side Piping
Pressure (MPa
)
35.100
35.200
35.300
35.400
35.500
35.600
3456789101112131415
Piping Length (m)
Outlet Air
Temperature (°C
)
220 230
4.950
5.000
5.050
5.100
5.150
5.200
5.250
5.300
5.350
3456789101112131415
Piping Length (m)
Current
(A)