5 
2. Specifications 
Indoor CS-E9PKEA 
Model 
Outdoor CU-E9PKEA 
Performance Test Condition  EUROVENT 
Phase, Hz  Single, 50 
Power Supply 
V 230 
 Min. Mid. Max. 
kW 0.85  2.50  3.00 
BTU/h 2900  8530  10200 
Capacity 
Kcal/h 730  2150  2580 
Running Current  A  –  2.40  – 
Input Power  W  170  515  710 
Annual Consumption  kWh  –  258  – 
W/W 5.00  4.85  4.23 
BTU/hW 17.06  16.56  14.37 
EER 
Kcal/hW 4.24  4.17  3.63 
Pdesign kW  2.5 
SEER (W/W)  7.1 
Annual 
Consumption 
kWh 123 
ErP 
Class   A++ 
Power Factor  %  –  90  – 
dB-A  39 / 26 / 23 
Indoor Noise (H / L / QLo) 
Power Level dB  55 / – 
dB-A  46 / – 
Cooling 
Outdoor Noise (H / L) 
Power Level dB  61 / – 
kW 0.85  3.40  5.40 
BTU/h 2900  11600  18400 
Capacity 
Kcal/h 730  2920  4640 
Running Current  A  –  3.3  – 
Input Power  W  165  700  1.31k 
W/W 5.15  4.86  4.12 
BTU/hW 17.58  16.57  14.05 
COP 
Kcal/hW 4.42  4.17  3.54 
Pdesign kW  2.8 
Tbivalent °C  -10 
SCOP (W/W)  4.4 
Annual 
Consumption 
kWh 891 
ErP 
Class   A+ 
Power Factor  %  –  92  – 
dB-A  40 / 27 / 24 
Indoor Noise (H / L / QLo) 
Power Level dB  56 / – 
dB-A  47 / – 
Heating 
Outdoor Noise (H / L) 
Power Level dB  62 / – 
Low Temp. : Capacity (kW) / I.Power (W) / COP  3.91 / 1.16k / 3.37 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP  3.33 / 1.29k / 2.58 
Max Current (A) / Max Input Power (W)  7.8 / 1.74k 
Starting Current (A)  3.3