2.
Cooling Operation
A. Room Temperature Control
(i) When the remote control setting temperature is less than 24°C
(ii) When the remote control setting temperature is 24°C and above
Compressor OFF temperature = Compressor ON temperature.
The operation frequency can be changed every 30 seconds.
30 minutes from the start of the operation, the compressor is operating at Fc max Hz.
The compressor stops when the intake air temperature reaches 1°C below internal setting temperature and continues for 3
minutes.
When the compressor stops, it will not begin operation for 3 minutes. (Time Delay Safety Control)
When the intake air temperature reaches the Compressor ON temperature, the Compressor starts operation.
When the compressor stops, the outdoor fan motor stops 30 seconds later.