1.
Temperature Shift
(i) Cooling, Soft Dry
Shift amount
CS-G95KE CS-G125KE
38°C Outdoor air temperature -1.0°C -1.0°C
30°C Outdoor air temperature <
38°C
-0.5°C -1.0°C
23°C Outdoor air temperature <
30°C
0.0°C 0.0°C
Outdoor air temperature < 23°C +1.0°C +1.0°C
Cooling Dry Heating
Powerful -4.0°C -3.0°C +6.0°C
(i) Heating
Shift amount
21°C Outdoor air temperature -1.5°C
17°C Outdoor air temperature < 21°C -1.0°C
13°C Outdoor air temperature < 17°C -1.0°C
9°C Outdoor air temperature < 13°C 0.0°C
5°C Outdoor air temperature < 9°C +0.5°C
1° Outdoor air temperature < 5°C +1.0°C
-3°C Outdoor air temperature < 1°C +1.0°C
Outdoor air temperature < -3°C +1.5°C
8 Operation Details
8.1. Function
Once the operation stars, the remote control setting temperature will be shifted internally based on the setting fan speed and
outdoor air temperature. In addition, if Sleep Mode or Powerful Mode are set, the temperature shift will be carried out.
Setting of Internal Setting Temperature
The internal setting temperature can be decided as follows:
Table a
Setting Temperature Shift based on outdoor air temperature.
Table b
Powerful Mode Shift.