Attached accessories
Applicable piping kit
CZ-3F5, 7AEN
CZ-4F5, 7, 10AN
SELECT THE BEST LOCATION
INDOOR UNIT
•
There should not be any heat source or steam near the
unit.
•
There should not be any obstacles blocking the air
circulation.
•
A place where air circulation in the room is good.
•
A place where drainage can be easily done.
•
A place where noise prevention is taken into
consideration.
•
Do not install the unit near the door way.
•
Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
•
Indoor unit of this room air conditioner shall be installed
on the wall in a height of at least 2.3 m.
OUTDOOR UNIT
•
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
•
There should not be any animal or plant which could be
affected by hot air discharged.
•
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
•
Do not place any obstacles which may cause a short
circuit of the discharged air.
Piping size Common Max. Max. Piping
Model Gas Liquid Length Elevation Length
(m) (m) (m)
G95KE 3/8” 1/4” 5 5 7
G125KE 1/2” 1/4” 5 5 7
Indoor/Outdoor unit installation diagram
•
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
74
S-G95KE CU-G95KE / CS-G125KE CU-G125KE