Attached accessories
Applicable piping kit
CZ-3F5, 7AEN
CZ-4F5, 7, 10AN
SELECT THE BEST LOCATION
INDOOR UNIT
There should not be any heat source or steam near the
unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
Indoor unit of this room air conditioner shall be installed
on the wall in a height of at least 2.3 m.
OUTDOOR UNIT
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could be
affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
Do not place any obstacles which may cause a short
circuit of the discharged air.
Piping size Common Max. Max. Piping
Model Gas Liquid Length Elevation Length
(m) (m) (m)
G95KE 3/8 1/4 5 5 7
G125KE 1/2 1/4 5 5 7
Indoor/Outdoor unit installation diagram
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
74
S-G95KE CU-G95KE / CS-G125KE CU-G125KE