EasyManua.ls Logo

Panasonic CS-G95KE CU-G95KE - Page 9

Panasonic CS-G95KE CU-G95KE
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Dimensions Height inch (mm) 10 - 31/32 (279) 21 - 9/32 (540)
Width inch (mm) 31 - 15/32 (799) 27 - 17/32 (699)
Depth inch (mm) 7 - 27/32 (199) 11 - 7/32 (285)
Net Weight lb (kg) 20 (9.0) 86 (39)
Compressor Type Rotary (2 cylinders)
rolling piston type
Motor Type Induction (4-poles)
Rated Output W 500
Air Circulation Type Cross-flow Fan Propeller Fan
Material AS + Glass Fiber 30% P.P + (Mica + Glass Fiber) 30%
Motor Type Transistor (4-poles) Induction (6-poles)
Input W 64
Rate Output W 20 20
Fan Speed Lo (Cool/Heat) rpm 980 / 1,010
Me (Cool/Heat) rpm 1,160 / 1,220
Hi (Cool/Heat) rpm 1,280 / 1,380 760
Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper
Fin material Aluminium Aluminium
Fin Type Slit Fin Corrugated Fin
Row / Stage (Plate fin configuration, forced draft)
2/14 1/20
FPI 21 19
Size (W × H × L) mm 614 × 294 × 25.4 782.9 × 508 × 22
Refrigerant Control Device Capillary Tube
Refrigeration Oil (c.c) SUNISO 4GDID or ATMOS M60
(350)
Refrigerant (R-22) g (oz) 780 (27.5)
Thermostat Electronic Control
Protection Device Electronic Control Electronic Control
Length mm C1, C2 ; 1033, C3 ; 400
Capillary Tube Flow Rate l/min C1, C2 ; 4.8, C3 ; 23.6
Inner Diameter mm C1, C2 ; 1.2, C3 ; 1.8
Air Filter Material
Style
P.P.
Honeycomb
Fan Motor Capacitor µF, VAC 2.0 µF, 400 VAC
Specifications are subject to change without notice for further improvement.