25
NOTE:
OFF Timer and OFF- ON Timer can only be set during the operation;
Timer setting can operate only once.
If the OFF/ON button on the remote control or the AUTO Switch on the indoor unit is pressed, the timer setting
will be cancelled.
If Auto Restart Control occurs, timer setting will be cancelled.
During the operation, if the ON Timer or ON-OFF Timer is set, the operation will be stopped.
11.3.10 About Cursor Key Which Points To “
““
“OFF”
””
”
On Remote Control
When the ON/OFF button on the remote control is pressed, the cursor key which points to “OFF” will appear or disappear to
indicate the ON/OFF status of the air conditioner.
For some reason (Ex. The signal of the remote control does not reach the signal receiver of the indoor unit.), the display of the
remote control will not correspond with the actual ON/OFF status of the indoor unit:
1. The air conditioner is running but the cursor key which points to “OFF” appears. The air conditioner can be stopped with
any button (Except for “ON/OFF”, “TIMER A”, “TIMER B”) pressed.
2.
The air conditioner is on standby, but the cursor key which points to “OFF” disappears. The air conditioner can be started
with any button (Except for “ON/OFF”, “TIMER A”, “TIMER B”) pressed.
12. Operation Control
12.1 Basic Function
12.1.1 Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting
processes. These shifting processes are depending on the air conditioner settings and the operation environment.
The final shifted value will be used as internal setting temperature and it is updated continuously whenever the
electrical power is supplied to the unit.
Remote Control Setting Temp. (16 ~30 )℃ ℃
Auto Operation Mode Shifting
Outdoor Air Temperature Shifting
Setting Temperature Limit Checking
(16
℃
~30
℃
)
Setting Temperature Limit Checking ( Min:16
; Ma℃ x:33 )℃
Internal Setting Temperature
AUTO
HEAT
COOL
DRY
AUTO
HEAT
COOL
DRY
Powerful Temperature Limit Che
c
king
Fan
Speed Shifting
Dry mode Shifting
Operating Shifting
Cooling/Heating Shifting