9 Close grille door by tighten with screw and close the front panel.
This equipment must be properly earthed.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the electrical safety in
case of the slipping out of the cord from the anchorage.
11.2.5. Wire Stripping And Connecting Requirement