10.2 Indoor Unit
10.2.1 How to Fix Installation Plate
The mounting wall is strong and solid enough to prevent if from the vibration.
Dimension
Model
ƻ
1
ƻ
2
ƻ
3
ƻ
4
ƻ
5
ƻ
6
S9***, S12*** 485 mm 82 mm 165 mm 158 mm 93 mm 145 mm
S18***, S24*** 585 mm 82 mm 165 mm 158 mm 219 mm 269 mm
The centre of installation plate should be at more than
ƻ
1 mm at right and left of the wall.
The distance from installation plate edge to ceiling should more than
ƻ
2.
From installation plate left edge to unit’s left side is
ƻ
3.
From installation plate right edge to unit’s right side is
ƻ
4.
ƻ
B : For left side piping, piping connection for liquid should be about
ƻ
5 from this line.
: For left side piping, piping connection for gas should be about
ƻ
6 from this line.
1 Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
o Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
a level gauge.
2 Drill the piping plate hole with ø70 mm hole-core drill.
o Line according to the left and right side of the installation plate. The meeting point of the extended line is
the center of the hole. Another method is by putting measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the distance namely 128mm for left and right hole
respectively.
o Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
side.
10.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping
1 Insert the piping sleeve to the hole.
2 Fix the busing to the sleeve.
3 Cut the sleeve until it extrudes about 15 mm from the wall
Caution
When the wall is hollow, please be sure to use the sleeve for tube
assembly to prevent dangers caused by mice biting the
connecting cable.
4 Finish by sealing the sleeve with putty or caulking compound at the
final stage.