10.2.4.1 Wiring stripping and connecting requirement
Wire stripping
5mm
or more
(gap between
wires)
ACCEPT
PROHIBITED
Conductor
over inserted
No loose strand when insert
Indoor/outdoor
connecting
terminal board
10 ± 1 mm
Conductor
fully inserted
PROHIBITED
Conductor not
fully inserted
10.2.4.2 Cutting and flaring the piping
1 Please cut using pipe cutter and then remove the burrs.
2 Remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping
end down to avoid the metal powder entering the pipe.
3 Please make flare after inserting the flare nut onto the copper pipes.