English
19
To learn more...
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
• Based on area activeness horizontal airfl ow direction will adjust either fi x 
at predetermined position or swing left/right periodically.
• The human activity sensor performance is infl uenced by indoor unit 
location, movement speed, temperature range, etc.
120º
7m
• The human activity sensor may: 
-  mistakenly detect an object with heat source & movement similar to human, such as pets, etc. 
-  mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor’s detection 
area. They may cause sensor malfunction.
Sunlight Sensor operation
Set
temperature
COOL/DRY
+1 °C
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
ECONAVI is activated, 
the unit maintains set 
temperature until a high 
sunlight intensity is detected. 
The sunlight sensor detects 
sunlight intensity during 
weather or day/night 
changes, and the unit adjusts 
temperature.
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
Operation conditions
Use this air conditioner under the following temperature range.
DBT  : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 43 26
Min. 16 11 16 11
F569797_YA0115-0.indb   19F569797_YA0115-0.indb   19 21/1/2015   10:24:15 AM21/1/2015   10:24:15 AM