EasyManuals Logo

Panasonic CS-UE12RKE Service Manual

Panasonic CS-UE12RKE
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© Panasonic Corporation 2015.
Order No: PAPAMY1501054CE
(PE9/12RKE)
(UE9/12RKE)
(UE18RKE)
Indoor Unit Outdoor Unit
CS-PE9RKE
CS-PE12RKE
CS-UE9RKE
CS-UE12RKE
CS-UE18RKE
CU-PE9RKE
CU-PE12RKE
CU-UE9RKE
CU-UE12RKE
CU-UE18RKE
Destination
Europe
E.Europe
Turkey
PRECAUTION OF LOW TEMPERATURE
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the products dealt with in this service information by anyone else could result in serious injury or death.

Table of Contents

Other manuals for Panasonic CS-UE12RKE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-UE12RKE and is the answer not in the manual?

Panasonic CS-UE12RKE Specifications

General IconGeneral
TypeAir conditioner indoor unit
IonizerNo
Multi-split-
Product colorWhite
Hose length (max)15 m
Inverter technologyYes
Dehumidifying capacity2 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3900 W
Cooling capacity in watts (min)850 W
Heating capacity in watts (max)5100 W
Heating capacity in watts (min)800 W
Cooling capacity in watts (nominal)3500 W
Cooling energy efficiency (EER, W/W)3.21
Heating energy efficiency (COP, W/W)3.64
Operating temperature (cooling) (T-T)5 - 43 °C
Operating temperature (heating) (T-T)-10 - 24 °C
Seasonal efficiency rating (cooling) (SEER)5.6
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)4000 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)3.8
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)3.5 kW
Energy efficiency class (cooling)A+
Power consumption (cooling) (max)1280 W
Power consumption (cooling) (min)255 W
Power consumption (heating) (max)1470 W
Power consumption (heating) (min)200 W
Annual energy consumption (cooling)219 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.4 kW
Energy efficiency class (heating) (Average heating season)A
Annual energy consumption (heating) (Average heating season)884 kWh
Indoor unit typeWall-mountable
Indoor unit depth214 mm
Indoor unit width870 mm
Indoor unit height290 mm
Indoor unit weight9000 g
Indoor units quantity1
Cooling airflow (indoor unit)762 m³/h
Heating airflow (indoor unit)804 m³/h
Indoor unit noise level (high speed)42 dB
Outdoor unit noise level- dB