Time Delay Safety Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Anti-Dew Formation Control
Automatic Fan Speed Mode
8.3. Soft Dry Mode Operation
 
 
 • 
• • 
• 
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
 
 
 • 
• • 
• 
During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
 
 
 • 
• • 
• 
Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and Outdoor Fan stop for 6
minutes.
 
 
 • 
• • 
• 
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
 
 
 • 
• • 
• 
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
 
 
 • 
• • 
• 
Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
 
 
 • 
• • 
• 
Same as Anti-Dew Formation Control for Cooling Mode operation.
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
 
 
 • 
• • 
• 
Fan speed off and on at Lo- speed.
 
 
 • 
• • 
• 
Deodorizing Control.