EasyManua.ls Logo

Panasonic CS-V18CKE - Page 5

Panasonic CS-V18CKE
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outdoor Unit
To protect compressor from reverse
rotation when there is an instantaneous
power failure.
60 Secs. Forced Operation Control
Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
Overload Protector
Inner protector.
Compressor Reverse Rotation
Protection Control
Outdoor Fan Operation Control
4-pole induction motor (2 speed).
For Cooling or Soft Dry operation
Hi-speed ............. When outdoor
temperature reaches to 31°C.
Lo-speed ............. When outdoor
temperature reaches to 29°C.
5
CS-V18CKE CU-V18CKE / CS-V24CKE CU-V24CKE

Table of Contents