D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed setting.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follow.
* When COMP is ON 1
2
3
(Shift to 4 when COMP is OFF)
* When COMP is OFF 4
5
4
←→
5
(Shift to 1 when COMP is ON)
* Start from 4 if the Thermostat is OFF during the start operation.
8.1.8. Outdoor Fan Motor Operation
6 pole induction, 1 speed 780 rpm (XE9DK), 810 rpm (XE12DK).
It starts when compressor starts operation and it stops 30 seconds after compressor stops operation.