8.3. Oxygen Enrich Operation
8.3.1. Purpose
Increase usage range by enable oxygen enrichment only operation.
8.3.2. Oxygen Enrichment Control -1
A. Indoor fan control
1. Air flow volume manual
Air flow volume as set by remote control. Speed same as for Cool mode.
2. Air flow volum auto
Repetition of 8 pattern (a ~ h) as shown below.
Each pattern, 10s
XE9DK XE12DK
Quiet
Program Air
No. B 820 870
No. A 790 840
No. C 760 810
W C 30 30
However, if combined operation with other mode, priority is given to fan control of other mode.
Priority: Cool - Dry - Fan - Heat > Ionizer > Oxygen
B. Indoor air direction control
1. Air flow direction manual, auto → same as cooling operation.
However when combined operation with other mode, priority is given to air flow direction control of other mode.
Priority Heat - Cool - Dry - Fan > Ionizer > Oxygen
C. Start & Cancel condition of Oxygen enrich operation
1. By remote control ON/OFF button.
a. During Ionizer and Air Conditioner is OFF, if Oxygen button is pressed
→ Oxygen only operation.
b. During Ionizer only operation, if Oxygen button is pressed
→ Ionizer + Oxygen enrich operation.
c. During Oxygen only operation, If Oxygen button is pressed
→ Oxygen operation stop.
d. During Oxygen only operation, if ON/OFF button is pressed
→ Mode (as remote control setting) operation + Oxygen operation.
e. During Cool, Fan, Heat, Dry, Ionizer operation, if Oxygen button is pressed
→Cool, Fan, Heat, Dry, Ionizer + Oxygen operation, if Oxygen button is pressed.
f. During Cool, Fan, Heat, Dry, Ionizer + Oxygen operation, if Oxygen button is pressed.
→ Cool, Fan, Heat, Dry, Ionizer operation.
g. During Cool, Fan, Heat, Dry, Ionizer + Oxygen operation, if ON/OFF button is pressed
→ All operation stop.