58
Combination
(Capacity)
Indoor Air
Temp. °C
DB
Outdoor Air Temp. °C WB
15 10 6 1 -5 -10 -15
Total Q
Input
Powe
Total Q
Input
Powe
Total Q
Input
Powe
Total Q
Input
Powe
Total Q
Input
Powe
Total Q
Input
Powe
Total Q
Input
Powe
2.5 + 5.0
16 6.72 1.19 6.72 1.49 6.72 1.65 4.35 1.59 3.90 1.61 3.30 1.52 2.50 1.38
18 6.59 1.24 6.57 1.55 6.56 1.71 4.26 1.63 3.83 1.65 3.24 1.57 2.46 1.42
20 6.40 1.29 6.42 1.61 6.40 1.77 4.16 1.66 3.76 1.69 3.19 1.61 2.43 1.45
21 6.46 1.31 6.44 1.63 6.43 1.79 4.27 1.70 3.86 1.72 3.28 1.64 2.50 1.48
22 6.46 1.33 6.46 1.65 6.46 1.81 4.38 1.73 3.96 1.76 3.36 1.66 2.56 1.50
24 6.53 1.36 6.51 1.69 6.53 1.86 4.61 1.81 4.16 1.82 3.53 1.72 2.69 1.56
3.5 + 3.5
16 6.72 1.19 6.72 1.49 6.72 1.65 4.35 1.59 3.90 1.61 3.30 1.52 2.50 1.38
18 6.59 1.24 6.57 1.55 6.56 1.71 4.26 1.63 3.83 1.65 3.24 1.57 2.46 1.42
20 6.40 1.29 6.42 1.61 6.40 1.77 4.16 1.66 3.76 1.69 3.19 1.61 2.43 1.45
21 6.46 1.31 6.44 1.63 6.43 1.79 4.27 1.70 3.86 1.72 3.28 1.64 2.50 1.48
22 6.46 1.33 6.46 1.65 6.46 1.81 4.38 1.73 3.96 1.76 3.36 1.66 2.56 1.50
24 6.53 1.36 6.51 1.69 6.53 1.86 4.61 1.81 4.16 1.82 3.53 1.72 2.69 1.56
3.5 + 4.2
16 6.72 1.19 6.72 1.49 6.72 1.65 4.35 1.59 3.90 1.61 3.30 1.52 2.50 1.38
18 6.59 1.24 6.57 1.55 6.56 1.71 4.26 1.63 3.83 1.65 3.24 1.57 2.46 1.42
20 6.40 1.29 6.42 1.61 6.40 1.77 4.16 1.66 3.76 1.69 3.19 1.61 2.43 1.45
21 6.46 1.31 6.44 1.63 6.43 1.79 4.27 1.70 3.86 1.72 3.28 1.64 2.50 1.48
22 6.46 1.33 6.46 1.65 6.46 1.81 4.38 1.73 3.96 1.76 3.36 1.66 2.56 1.50
24 6.53 1.36 6.51 1.69 6.53 1.86 4.61 1.81 4.16 1.82 3.53 1.72 2.69 1.56
Total Q: Total Heating Capacity (kW)
Input Power (kW)