Heating Characteristic
[Condition] Room temperature: 20°C (DBT), 12°C (WBT)
Operation condition: High fan speed
Piping length: 5.0 m
Voltage: 230V, 50Hz
A) Indoor unit capacity: Heating (1.6), CS-MTZ16TKEW
Outdoor Air Temperature (°C)
Indoor Discharge Air
Temperature (°C)
26.000
26.800
27.600
28.400
29.200
30.000
30.800
31.600
32.400
33.200
34.000
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
Outdoor Air Temperature (°C)
Current
(A)
3.100
3.240
3.380
3.520
3.660
3.800
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa)
1.700
1.760
1.820
1.880
1.940
2.000
2.060
2.120
2.180
2.240
2.300
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12