Heating Characteristic
[Condition] Room temperature: 20°C (DBT), 12°C (WBT)
Operation condition: High fan speed
Piping length: 5.0 m
Voltage: 230V, 50Hz
C) Indoor unit capacity: Heating (3.5 + 3.5), CS-TZ35TKEW + CS-TZ35TKEW
Outdoor Air Temperature C)
Indoor Discharge Ai
r
Temperature C)
TZ35TKEW TZ35TKEW
25.400
26.000
26.600
27.200
27.800
28.400
29.000
29.600
30.200
30.800
31.400
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
Outdoor Air Temperature (°C)
Current
(A)
4.300
4.450
4.600
4.750
4.900
5.050
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa)
1.740
1.781
1.822
1.863
1.904
1.945
1.986
2.027
2.068
2.109
2.150
-16-14-12-10-8-6-4-2024681012