– 17 –
MAC9512086C2
CS-C73KE
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
Operation Details
Cooling Operation Time Diagram
* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
* SLo: Indoor Fan rotates at 4 second intervals at low speed.
<Description of operation>
d g : Time Delay Safety Control (waiting for 3 minutes)
g – h : 60 sec. Forced Operation
h – o : 7 min. Time Saved Control
q – t : Anti Freezing Control
Operation
Stop
Indoor
Fan
Comp.
SLo SLo SLo SLo
ON ONOFF
stop stop stop
30"
stop
30"160"
1
40"
40"
20"
.
.
.
.
2
.
.
.
.
a
b
c
def
g
hi
j
klmnopq
rs
tuvwxyz
Basic Time
Compressor
Indoor Fan
Outdoor Fan
Operation LED
1’
3’
1’
7’ 1’
4’
1.5K
ON
OFF
Intake
Temperature
Set Temp.
10°C
2°C
Pipe temperature
Untitled-1 6/28/00, 4:11 PM17