– 17 –
MAC9512086C2
CS-C73KE
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
• Fan speed rotates in the range of Hi to Me.
• Deodorizing Control.
Operation Details
Cooling Operation Time Diagram
* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
* SLo: Indoor Fan rotates at 4 second intervals at low speed.
<Description of operation>
d – g : Time Delay Safety Control (waiting for 3 minutes)
g – h : 60 sec. Forced Operation
h – o : 7 min. Time Saved Control
q – t : Anti Freezing Control
Operation
Stop
Indoor
Fan
Comp.
SLo SLo SLo SLo
ON ONOFF
stop stop stop
30"
stop
30"160"
1
40"
40"
20"
✕
.
.
.
.
2
✕
.
.
.
.
a
b
c
def
g
hi
j
klmnopq
rs
tuvwxyz
Basic Time
Compressor
Indoor Fan
Outdoor Fan
Operation LED
1’
3’
1’
7’ 1’
4’
1.5K
ON
OFF
Intake
Temperature
Set Temp.
10°C
2°C
Pipe temperature
Untitled-1 6/28/00, 4:11 PM17