9.6.2. Cooling/Dry Operation
AIR SWING; AUTO
• When AIR SWING-AUTO of remote control button is pressed, the upper air outlet swings in the range of the upper limit and
the lower limit.
• When fan motor stop, vertical airflow direction louver does not swing.
• When OFF/ON button is pressed again, the vertical airflow direction louver closes.
(Fig. b)
AIR SWING; MANUAL
• When AIR SWING-MANUAL of remote control button is pressed, upper air outlet's vertical airflow direction louver position
changes, when button is released, the vertical airflow direction louver position remain at the position.
• When OFF/ON button is pressed again, the vertical airflow direction louver closes.
9.6.3. Heating Operation
AIR SWING; AUTO
• According to indoor unit heat exchanger temperature, the vertical airflow direction louver position is set.
• When OFF/ON button is pressed again, the vertical airflow direction louver closes.
Single Type Multi Type
During defrost operation, as cold draft prevention, the vertical airflow direction louver is set to position C.
(Fig. c)
(Fig. d)
9.6.4. Lower air outlet Operation
Air blown out is controlled with open and close of lower air outlet shutter.
9.6.5. Left and right wind direction louver Operation
Manual operation. Position is adjusted with the knob of the left and right louver.
Heat Exchanger Temperature Vertical airflow direction louver position
A zone Position A
B zone Position B
C zone Position A
Heat Exchanger Temperature Vertical airflow direction louver position
A zone Position B
B zone Position B
C zone Position A