9.5. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit).
[Cooling, Dry, Fan] During upper air outlet discharge
[Cooling, Dry, Fan] During upper and lower air outlets discharge
[Heating] During upper air outlet discharge
[Heating] During upper and lower air outlets discharge
Remote Control O O O O O QUIET
Tab (rpm) SHi Hi Me+ Me Me- Lo Lo+ SLo
CS-E9GFEW 660 620 560 510 460 410 360 250
CS-E12GFEW 680 640 580 530 480 430 370 250
CS-E18GFEW 800 760 710 660 610 570 490 250
Remote Control O O O O O QUIET
Tab (rpm) SHi Hi Me+ Me Me- Lo Lo+ SLo
CS-E9GFEW 660 620 560 510 460 410 360 250
CS-E12GFEW 680 640 580 530 480 430 370 250
CS-E18GFEW 800 760 710 660 610 570 490 250
Remote Control OOOOOQUIET
Tab (rpm) SHi Hi Me+ Me Me- Lo Lo+ SLo
CS-E9GFEW 670 630 570 520 460 410 360 250
CS-E12GFEW 690 650 590 530 470 410 360 250
CS-E18GFEW 910 870 800 740 670 610 490 250
Remote Control OOOOOQUIET
Tab (rpm) SHi Hi Me+ Me Me- Lo Lo+ SLo
CS-E9GFEW 670 630 570 520 460 410 360 250
CS-E12GFEW 690 650 590 530 470 410 360 250
CS-E18GFEW 900 870 800 740 670 610 490 250