68
12 Disassembly and Assembly Instructions
12.1. Indoor Unit
1. Removal of Suction Grille
Push the knob of Suction Grille (2 places) to the “Open”
position to remove Grille.
2. Removal of Front Grille
Remove screws, 2 at top and 2 at bottom to remove the
Front Grille.
3. Removal of Control Board Casing
a. Remove the ground line of the heat exchanger at right
side (1 screw).
b. Remove the screw of the Control board casing at right
side.
Fig. 1
Fig. 2
Fig. 3
High voltages are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding
with repair work. Failure to heed this caution may result in electric shocks.