EasyManua.ls Logo

Panasonic CU-E18CKR - Page 31

Panasonic CU-E18CKR
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
shown below.
8.1.13. Delay OFF Timer Control
Delay OFF timer can be set using remote control, the unit with timer set will stop operate at set
time.
8.1.14. Auto Restart Control
1. When the power supply is cut off during the operation of air
conditioner, the compressor will re-operate within three to four
minutes (there are 10 patterns between 2 minutes 58 seconds and
3 minutes 52 seconds to be selected randomly) after powersupply
resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
8.1.15. Indication Panel
LED POWER
MONITOR
POWER QUIET TIMER POWERFUL
Color Green Green Orange Orange Orange
Green
Light ON Compressor
ON
Operation ON Quiet Mode ON Timer Setting
ON
Powerful
Mode ON
Ion
Mode
Light OFF Compressor
OFF
Operation OFF Quiet Mode
OFF
Timer Setting
OFF
Powerful
Mode OFF
Ion
Mode
Note:
- If POWER LED is blinking, the possible operations of the unit are
Hot Start, during Deice operation, operation mode judgment, or
delay ON timer sampling.
- If Timer LED is blinking, there is an abnormality operation occurs.
- If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.
Power Monitor LED Control Frequency