antioxidant are available on the market. However, the constituents 
of these are widely varied, and some are anticipated to corrode 
the piping materials, or adversely affect HFC 
refrigerant,lubricating oil, etc. Exercise care when using an 
oxidation preventive.
10.4.7. Servicing Tips 
The drier must also be replaced whenever replacing the refrigerant cycle parts. Replacing the 
refrigerant cycle parts first before replacing the drier. The drier is supplied in a vacuum pack. 
Perform brazing immediately after opening the vacuumpack, and then start the vacuum within 
two hours. In addition, the drier also needs to be replaced when the refrigerant has leaked 
completely. (Applicable for drier models only)
11. Installation Instructions 
Required tools for Installation Works
1. Philips screw 
driver 
5. Spanner 9. Gas leak 
detector
13.
Multimeter
2. Level gauge 6. Pipe cutter
10.
Measuring tape
14.
Torque wrench
18 N   m (1.8 kgf   m) 
55 N   m (5.5 kgf   m) 
65 N   m (6.5 kgf   m)
3. Electric drill, hole 
core drill (ø70 mm)
7. Reamer
11.
Thermometer
15.
Vacuum pump
4. Hexagonal wrench 
(4 mm)
8. Knife
12.
Megameter
16.
Gauge manifold
11.1. Safety Precautions 
- Read the following “SAFETY PRECAUTIONS” carefully before 
installation.
- Electrical work must be installed by a licensed electrician. Be sure 
to use the correct rating of the power plug and main circuit for the 
model to be installed.
- The caution items stated here must be followed because these 
important contents are related to safety. The meaning of each 
indication used is as below. Incorrect installation due to ignoring 
of the instruction will cause harmor damage, and the seriousness 
is classified by the following indications.
 
This indication shows the possibility of causing death or serious injury.