EasyManua.ls Logo

Panasonic CU-E18DBE

Panasonic CU-E18DBE
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DISPOSAL OF OUTDOOR UNIT DRAIN WATER
If a drain elbow is used, the unit should be placed on a
stand which is taller than 3 cm.
If the unit is used in an area where temperature falls below
0°C for 2 or 3 days in succession, it is recommended not to
use a drain elbow, for the drain water freezes and the fan
will not rotate.
CHECK THE DRAINAGE
AUTO SWITCH OPERATION
The following operations can be performed by pressing the
AUTO switch.
1. AUTO OPERATION MODE
The Auto operation will be activated immediately once the
Auto Switch is pressed.
2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING
PURPOSE)
The Test Run operation will be activated if the Auto Switch
is pressed continuously for more than 5 sec. to below 8 sec.
A beep sound will occur at the fifth sec., in order to identify
the starting of Test Run operation.
CHANGING THE REMOTE CONTROL TRANSMISSION
CODE
1. Press AUTO SW continuously for 11 seconds (buzzer
sound = pep pep pep)
2. After 11 seconds, release AUTO SW, then press Remo-
Con TIMER
SW continuously for 5 seconds. Reset
code will be transmitted. After the reset code is transmitted,
release TIMER
SW.
3. Press Remo-Con OFF/ON button. The new Remo-Con
No. will be accepted and memorized, after which the new
Remo-Con No. can be used.
61
CS-E15DTEW CU-E15DBE / CS-E18DTEW CU-E18DBE / CS-E21DTES CU-E21DBE

Table of Contents

Other manuals for Panasonic CU-E18DBE

Related product manuals