3.2. CS-E18DTEW CU-E18DBE
Unit CS-E18DTEW CU-E18DBE
Cooling Capacity kW
kcal/h
BTU/h
5.00 (0.90 - 5.40)
4,300 (770 - 4,640)
17,100 (3,070 - 18,400)
Heating Capacity kW
kcal/h
BTU/h
6.10 (0.90 - 7.60)
5,250 (770 - 6,540)
20,800 (3,070 - 25,900)
Moisture Removal l/h
Pint/h
2.8
(5.9)
Power Source (Phase, Voltage, Cycle) ø
V
Hz
Single
230 - 240
50
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Lo m
3
/min (cfm) Cooling; 9.8 (350) —
Heating; 8.6 (300)
Me m
3
/min (cfm) Cooling; 11.2 (390) —
Heating; 10.7 (380)
Hi m
3
/min (cfm) Cooling; 12.5 (440) 40.0 (1,410)
Heating; 12.7 (450)
dB (A) Cooling; High 46, Low 39 Cooling; 47
Heating; High 47, Low 35 Heating; 48
Noise Level
Power level dB Cooling; High 59 Cooling; High 60
Heating; High 60 Heating; High 61
Electrical Data Input Power W Cooling; 1,660 (255 - 1,890)
Heating; 1,820 (260 - 2,380)
Running Current A Cooling; 7.5 - 7.4
Heating; 8.2 - 8.1
EER W/W Cooling; 3.01 (3.53 - 2.86)
BTU/hW Cooling; 10.3 (12.0 - 9.7)
COP W/W Heating; 3.35 (3.46 - 3.19)
BTU/hW Heating; 11.4 (11.8 - 10.9)
Starting Current A 8.2
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 1/2”
L ; Half Union 1/4”
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
8