8.4. Random Auto Restart Control
- If there is a power failure, operation will be automatically restarted
after 3 to 4 minutes when the power is resumed.
It will start with previous operation mode and airflow direction
(Time Delay Safety Control is valid) as the operation was not
stopped by Remote Control or Main Unit (Touch Control Panel).
- Restart time is decided randomly with 5 parameters:-
- Intake air temperature.
- Setting temperature.
- Fan speed.
- Air Swing blade position.
- Indoor heat exchanger temperature.
- Auto Restart Control is not available when Timer is set.
- If Economy operation is set during power failure, Economy
operation will not start automatically along with previous
operation mode after power resume.
- This control can be omitted by opening jumper JX1.
8.5. Fan Speed Control
- Manual Fan Speed Control
Basic fan speed adjustment (3 setting, from Lo, Med to Hi) can be
carried out by using the Fan Speed Selection Button/Pad at the
Remote Control or Main Unit (Touch Control Panel).
8.6. Airflow Direction Control
8.6.1. Horizontal Airflow Direction
- When Air Swing Button/Pad is pressed with Remote Control or
Main Unit (Touch Control Panel) in the Auto Airflow, the airflow
direction louver swings side to side within the full swing range as