EasyManua.ls Logo

Panasonic CW-XC120AU - Timer Table

Panasonic CW-XC120AU
47 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Not
indicated
Carbon resistor
Tolerance (+-) 5%
Metal oxide
resistor
Tolerance (+-) 1%
- Indications for capacitor
Unit - ... F
-P...pF
Type -Not indicated...ceramic capacitor
-(S)...S series aluminium electrolytic capacitor
-(Z)...Z series aluminium electrolytic capacitor
-(SU)...SU series aluminium electrolytic capacitor
-(K)...K series aluminium electrolytic capacitor
-(P)...P series polyester system
-(SXE)...SXE series aluminium electrolytic capacitor
-(SRA)...SRA series aluminium electrolytic capacitor
-(KME)...KME series aluminium electrolytic capacitor
- Diode without indication...MA165
- Circuit Diagram is subject to change without notice for further
development.
19.4. Timer Table
Name Time Test Mode (Shortened CN-
TEST pin)
Remarks
Hour Timer
1 hr.
10 min.
1 min.
1 min.
10 sec.
1 sec.
Time delay Safety Control 2 min. 58 sec. 0 sec.
Forced Operation 60 sec. 0 sec.
Time Save Control 7 min. 42 sec.
Freeze Prevention Control 3 min. 0 sec.
Compressor Reverse Rotation
Detection
2 min. 0 sec.
Starting Current Control 1.6 sec. 0 sec.
Random Auto Restart Control 0 ~ 62 sec. 0 ~ 6.2 sec. Add value to
Time
Safety
Control.
[MAICO] Printed in Malaysia