EasyManua.ls Logo

Panasonic DP-180 - Scan Parameters; Select Mode

Panasonic DP-180
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
UF-9000
JUN 2004
Ver. 2.0
DP-180/190
Note:
These error codes will appear only when the optional accessories are installed.
E4- 10 Exhaust Fan Motor Rotation
(Fuser Unit Side)
1. Exhaust Fan connector is disconnected.
2. Exhaust Fan is defective.
3. LVPS connector is disconnected.
4. LVPS is defective.
5. Engine PCB is defective.
E5: System Error
Code Function Check Points
E5- 05 SPC Firmware Failure 1. SPC PCB is defective.
E5- 11 Thermistor, Toner Sensor 1. SC/Engine PCB connector is disconnected.
2. SC/Engine PCB is defective.
E5- 12 Main CPU/SPC Interface Error 1. SC/SPC PCB connector is disconnected.
2. SC/SPC PCB is defective.
E7: Optional Unit Error
Code Function Check Points
E7- 90 Hardware Key Error Incorrect Hardware Key is installed.
E13: Low Toner or Out of Toner
Code Function Check Points
E13 TONER IS RUNNING LOW
or
OUT OF TONER
1. Toner Cartridge is incorrectly installed.
2. Out of Toner.
3. Low Toner Sensor is disconnected.
4. Low Toner Sensor is defective.
5. Engine PCB connector is disconnected.
6. Engine PCB is defective.
E4: Fuser Unit Error
Code Function Check Points

Other manuals for Panasonic DP-180

Related product manuals