TECHNICAL SPECIFICATIONS
MCUK000601C8 Section 5 Issue 1
Service Manual – 29 – Revision 0
GSM1800 Full Rate Speech
The reference sensitivity performance in terms of frame erasure, bit error, or residual bit error rates (whichever is
appropriate) is specified in the following table, according to the propagation conditions.
The reference sensitivity level is <-102dBm.
NOTE: 1 α 1.6. The value of a can be different for each channel condition but must remain the same for FER and
class Ib RBER measurements for the same channel condition.
GSM1800 Half Rate Speech
The reference sensitivity performance in terms of frame erasure, bit error, or residual bit error rates (whichever is
appropriate) is specified in the following table, according to the propagation conditions.
Blocking:
Measurement Conditions:
Wanted carrier is 3dB above reference sensitivity.
Interferer is CW.
Channels
Propogation Conditions
TUhigh
Propogation Conditions
RA
Propogation Conditions
HT
Static Conditions
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
TCH/FS FER 4.478*α 13400 0.122*α 164000
class Ib (RBER) 0.32/α 1,500,000 0.41/α 20,000,000
class II (RBER) 8.333 60,000 7.5 24000 9.333 30000 2.439 8200
Channels
Propogation Conditions
TUhigh
Propogation Conditions
RA
Propogation Conditions
HT
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
TCH/HS (FER) 4.706 12750
TCH/HS class Ib (BFI=0) 0.426 141000
TCH/HS class II (BFI=0) 7.725 25500 8735 20000 7600 20000
TCH/HS (UFR) 6.383 9400
TCH/HSL class Ib ((BFI or UFI)=0) 0.291 206000
Frequency
Small MS level in dBµVemf()
GSM900 GSM1800
FR ±600 kHz to FR ±800 kHz 70 70
FR ±800 kHz to FR ±1.6 MHz 70 70
FR ±1.6 MHz to FR ±3 MHz 80 80
915 MHz to FR -3 MHz 90 -
FR ±3 MHz to FR 980 MHz 90 -
FR ±600 kHz to FR ±800 kHz - 87
1785 MHz to FR - 3 MHz - 87
835 MHz to <915 MHz 113 -
>980 MHz to 1000 MHz 113 -
100 kHz to <835 MHz 90 -
>1000 MHz to 12.75 GHz 90 -
100 kHz to 1705 MHz - 113
>1705 MHz to<1785 MHz - 101
>1920 MHz to 1980 MHz - 101
>1980 MHz to 12.75 GHz - 90