TECHNICAL SPECIFICATIONS
Issue 1 Section 5 MCUK000601C8
Revision 0 – 28 – Service Manual
5.1.6. Output Level, Dynamic Operation
GSM900
GSM1800
5.1.7. Residual Peak Power
70dBc (BW = 300kHz)
5.2. Rx Characteristics
5.2.1. Sensitivity
GSM900 Full Rate Speech
The reference sensitivity performance in terms of frame erasure, bit error, or residual bit error rates (whichever is
appropriate) is specified in the following table, according to the propagation conditions.
The reference sensitivity level is <-102dBm.
NOTE: 1 α 1.6. The value of a can be different for each channel condition but must remain the same for FER and
class Ib RBER measurements for the same channel condition.
GSM900 Half Rate Speech
The reference sensitivity performance in terms of frame erasure, bit error, or residual bit error rates (whichever is
appropriate) is specified in the following table, according to the propagation conditions.
Power Control
Level
Transmitter Output Power
(dBm)
Tolerance for Conditions (dB)
Normal Extreme
TBA
Power Control
Level
Transmitter Output Power
(dBm)
Tolerance for Conditions (dB)
Normal Extreme
TBA
Channels
Propogation Conditions
TUhigh
Propogation Conditions
RA
Propogation Conditions
HT
Static Conditions
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
TCH/FS FER 6.742*α 8900 0.122*α 164000
class Ib (RBER) 0.42/α 1,000,000 0.41/α 20,000,000
class II (RBER) 8.33 120,000 7.5 24000 9.333 60000 2.439 8200
Channels
Propogation Conditions
TUhigh
Propogation Conditions
RA
Propogation Conditions
HT
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
Test Limit
error rate
%
Minimum
No. of
samples
TCH/HS (FER) 4.598 13050
TCH/HS class Ib (BFI=0) 0.404 148500
TCH/HS class II (BFI=0) 7.725 25500 8500 20000 7600 20000
TCH/HS (UFR) 6.250 9600
TCH/HSL class Ib ((BFI or UFI)=0) 0.269 227000