TEST AND MEASUREMENT
MCUK000601C8 Section 6 Issue 1
Service Manual – 39 – Revision 0
Figure 6.11: PC Screen (SCRN9)
3. On the PC, select NORMAL MODE and press ENTER.
4. Press F10 on the PC.
5. After approximately 1second, set the interface cable switch to ON (position is marked by a dot).
Entering Call Mode from Test Mode
Ensure that a fully-charged battery is attached to the telephone.
The screen of the PC should resemble the one shown below:
Figure 6.12: PC Screen (SCRN11)
1. At the PC, change the SOFT SIM field to read <ENABLE>. Press ENTER.
2. At the PC, change the TEST MODE field to read <TERM>. Press ENTER.
The UUT will power down and up again. If the UUT is connected to a GSM test set,after a delay of approximately five
seconds, the UUT will register service.
3. To return to test mode, set the SOFT SIM field to <DISABLE> and set the TEST MODE field to <TEST>. Press Enter.