TEST AND MEASUREMENT
MCUK000601C8 Section 6 Issue 1
Service Manual – 45 – Revision 0
Figure 6.19: RSSI dB field
6. If the measured power is not -90±1, then make the following calculation:
RSSI offset value = [-(90+MEASURED RSSI VALUE)] x 2
=[ -90 - MEASURED RSSI VALUE] x 2,
for example [-(90 + (95))] x 2
= [-90 - (-95)] x 2
= 10
Record the result.
7. At the channelbox, press F7 to view data.
Figure 6.20: RSSI reading 1
8. Select TRIM OTHER and make a note of the RSSI COMP GSM reading.