5-36
5.1.6 Table of Special Data Registers for FP-e
The special data registers are one word (16-bit) memory areas which store specific information.
FP-e (A: Available, N/A: Not available)
Register
No.
Name Descriptions
Read
-ing
Writ-
ing
DT9000
Self-diagnostic error
code
The self-diagnostic error code is stored here
when a self-diagnostic error occurs.
A N/A
DT9001
FP-e screen display
switching
Switches the FP-escreen to the screen of the
mode specified.
K0: N mode first screen
K1: N mode second screen
K2: S mode first screen
K3: S mode second screen
K4: R mode first screen
K5: R mode second screen
K6: I mode first screen
K7: I mode second screen
A N/A
DT9002
DT9003
Analog input data Ch.0 analog input data (2-word real data) A N/A
DT9004
DT9005
Analog input data Ch.1 analog input data (2-word real data) A N/A
DT9014
Operation auxiliary
register for data
shift instruction
One shift-out hexadecimal digit is stored in bit
positions 0 to 3 when the data shift instruction,
F105 (BSR) or F106 (BSL) is executed. The
value can be read and written by executing the
F0 (MV) instruction.
DT9015
DT9016
Operation auxiliary
register for division
instruction
The divided remainder (16-bit) is stored in
DT9015 when the division instruction F32(%)
or F52(B%) instruction is executed. The
divided remainder (32-bit) is stored in DT9015
and DT9016 when the division instruction
F33(D%) or F53(DB%) is executed. The value
can be read and written by executing the
F0(MV) instruction.
A A
DT9017
Operation error
address (hold type)
After commencing operation, the address
where the first operation error occurred is
stored. Monitor the address using decimal
display.
DT9018
Operation error
address (non-hold
type)
The address where an operation error
occurred is stored. Each time an error occurs,
the new address overwrites the previous
address. At the beginning of a scan, the
address is 0. Monitor the address using
decimal display.
DT9019
2.5 ms ring counter
Note1)
The data stored here is increased by one
every 2.5 ms. (H0 to HFFFF)
Difference between the values of the two
points (absolute value) x 2.5 ms = Elapsed
time between the two points.
A N/A